Modbus to FF, PA, HART Converter,apply to TTL, RS232,RS485 transmitter

Modbus to FF, PA, HART Converter,apply to TTL, RS232,RS485 transmitter
Product Detailed
1. provide OEM 2. Modbus to FF, PA, HART 3.TTL,RS232,RS485 4.66mm/80mm/96mm, may be customized

 Modbus to FF, PA, HART Converter,apply to TTL, RS232,RS485 transmitter  

NCS-MF105, MODBUS-FF Converter 

NCS-MF105 is a converter device for MODBUS-RTU protocol to FF protocol. It is able to integrate device/board with MODBUS communication interface to FF bus system. Bus power supply is selected by NCS-MF105, and NCS-MF105 can provide power supply to the boards the user provides.

As a MODBUS host, NCS-MF105 communicates with the device with MODBUS-RTU interface, it can achieve read/write operation for MODBUS register data via FF transducer blocks, and convert MODBUS data to FF communication system via FF standard AI,AO,DI,DO function blocks.

Features

Compliant with FF standard, provide FF communication ability to MODBUS device

Support Link Master function

Support AI, AO, DI, DO, PID function blocks

Support function blocks instantiation

Support standard DD or EDD specification

Electrical interface connected with MODBUS device supports TTL level, RS485 and RS232

Able to provide 3.3V or 5V power supply output

NCS-MF105 Application

Gas detector

Analyzer

Positioner

Any smart device with MODBUS protocol

Bus signalIEC61158-2 physical layer standard
Bus power supply9 ~ 32V
Operating temperature-40 ~ 85°C
Static current≤14mA
Humidity range5% ~ 95%,non dew

Mechanism size

Dia 66 mm for TTL level

80*80mm for RS485 and RS232

(can be customized)

                                   

NCS-MP105,  MODBUS-PA Converter 

NCS-MP105 is a converter device for MODBUS-RTU protocol to PROFIBUS PA protocol. It is able to integrate device/board with MODBUS communication interface to PROFIBUS PA bus system. Bus power supply is selected by NCS-MP105, and NCS-MP105 can provide power supply to the boards the user provides.

As a MODBUS host, NCS-MP105 communicates with the device with MODBUS-RTU interface, it can achieve read/write operation for MODBUS register data via PA transducer blocks, and convert MODBUS data to PA communication system via PA standard AI,AO,DI,DO function blocks.

Features

Compliant with PROFIBUS PA standard, provide PROFIBUS PA communication ability to MODBUS device

Support PROFIBUS DPV1 and PROFIBUS PA 3.01

SupportAI ,AO,DI,DO standard function blocks

Support GSD5.0 and standard EDD

Support standard DD or EDD specification

Electrical interface connected with MODBUS device supports TTL level, RS485 and RS232

Able to provide 3.3V or 5V power supply output

Others refer to NCS-MF105

NCS-MH105, MODBUS-HART Converter 

NCS-MH105 is a converter device for MODBUS-RTU protocol to HART protocol. As a MODBUS host, NCS-MH105 communicates with the device with MODBUS-RTU communication ability, it converts the data in the device to HART device variables, and supports 4~20mA current output.

NCS-MH105 converter supports 4 dynamic variables, 6 device variables, all HART universal commands, common practice HART commands and standard MODBUS-RTU protocol. The mechanism size is 96 mm * 56 mm, which not only matches standard Adam module housing, also can be installed to device through positioning hole.

HART Bus gives power supply to NCS-MH105 converter. RS485 electrical interface requires an external 5V power supply.

Features

Compliant with HART 6.0 standard, provide HART communication ability to MODBUS device

Support all HART universal commands and common practice HART commands

Support device specific commands ondemand

Support HART multidrop mode

Support HART communication burst mode

Support handheld 375/475

Electrical interface connected withMODBUS device supports TTL level, RS485 and RS232

Bus signal

4~20mA output with HART protocol,    

digital communication

Bus power supply11.9 ~ 42V
Operating temperature-40 ~ 85°C
Humidity range5% ~ 95%,non dew

Mechanism size

96*56mm (can be customized)