- Software Development[1]
- Computer Cables & Connectors[1]
- Modems[3]
- Other Computer Parts[2]
- Software[3]
- Terminals[1]
- Electronic & Instrument Enclosures[1]
- Other Electrical Equipment[10]
- Power Distribution Equipment[1]
- Inverters & Converters[9]
- Voltage Regulators/Stabilizers[1]
- Integrated Circuits[10]
- Semiconductors[1]
- Multilayer PCB[3]
- Other PCB & PCBA[9]
- Other Machinery[1]
- Instrument Parts & Accessories[1]
- Measuring & Analysing Instrument Stocks[1]
- Pressure Transmitters[10]
- Temperature Instruments[4]
- Access Control System[2]
- Other Telecommunications Products[1]
- VoIP Products[1]
- Wireless Networking Equipment[2]
- Contact Person : Ms. Jin Guangshu
- Company Name : Microcyber Corporation
- Tel : 86-24-31217278
- Fax : 86-24-31217279
- Address : Liaoning,Shenyang,#1Building , 17-8 Wensu Street, Hunnan New District
- Country/Region : China
- Zip : 110179
Related Product Searches:oil pressure transmitter,High Quality,oil pressure transmitter, pressure flow transmitter,NCS-PT105II
oil pressure transmitter
Brief Introduction
NCS Series of Intelligent Transmitters are digital, intelligent, network-based, merged with advanced, reliable and stable sensor technology, to be designed as a new generation of Fieldbus Intelligent Transmitter.
Performance Index
Precision | For range 2 ±0.1% of Span is for 0.5 URL≤Span ≤ URL; ±[0.05+0.025 ×(URL / Span)]% of Span is for Span<0.5 URL. For other ranges ±0.075% of Span is for 0.1 URL≤Span ≤ URL; ±[0.025+0.005 ×(URL / Span)]% of Span is for Span<0.1 URL |
Temperature effect | Total effects per 28°C(50°F)change: For range 2 ±[0.05% URL +0.25% Span] For other ranges Span≥0.1 URL: ±[0.019% URL +0.125% Span] Span<0.1 URL: ±[0.025% URL +0.125% Span] |
Long time stability | In 12 months, ±0.1% of maximum range |
Static pressure effect | For range 2 ±1% / 13.8MPa For range 3 ±0.5% / 13.8Mpa For other ranges ±0.25%/13.8MPa |
Location installed effect | The maximum of the zero point movement is 0.24kPa |
Power effect | < 0.005%/V of range calibrated |
Explosion-proof | intrinsically safety Ex ia II C T4 |
Explosion-proof level | IP65 or IP67 |
Vibration effect | Meet GB/T 2423-1995 |
Electromagnetic compatibility | Meet GB/T 17626-1998(IEC 61326-1:1997) |
oil pressure transmitter