Microcyber Corporation
Main products:pressure transmitter,temperature transmitter
Products
Contact Us
  • Contact Person : Ms. Jin Guangshu
  • Company Name : Microcyber Corporation
  • Tel : 86-24-31217278
  • Fax : 86-24-31217279
  • Address : Liaoning,Shenyang,#1Building , 17-8 Wensu Street, Hunnan New District
  • Country/Region : China
  • Zip : 110179

Universal input field mounted Low-copper aluminum alloy housing temperature indicating transmitter NCS-TT105 with Hart protocol

Universal input field mounted Low-copper aluminum alloy housing temperature indicating transmitter NCS-TT105 with Hart protocol
Product Detailed
1.Number of channels: 2 2.Sensor type: Resistance---Pt100, Cu50, Cu100, 0~50aa, 0~2000aa 3.Bus signal: 31.25kbit/s

 Universal input field mounted Low-copper aluminum alloy housing

temperature indicating transmitter NCS-TT105 with Hart protocol

 

Brief Introduction

NCS-TT105 temperature transmitter is a new generation of smart transmitters with FF, Profibus PA or HART technology. NCS-TT105 transmitter integrates abundant function blocks and realizes not only normal measurement functions but also complicated control strategy.

1.Number of channels: 2

2.Sensor type: Resistance---Pt100, Cu50, Cu100, 0~50Ω, 0~2000Ω

3.Bus signal: 31.25kbit/s

4.Power: 9~32VDC

5.Current consumption (static): ≤14mA

 

Figure                                           

 

Smart Transmitter Size (Unit: mm)

 

Smart Transmitter Structure (Unit: mm)

 

1

Front cover

2

O-ring

3

Display board housing

4

LCD board

5

Positioning column

6

Communication board

7

Instrument board

8

Isolation board

9

Terminal board

10

Screw

11

Wiring hole

12

Screw

13

Name plate

14

S/Z hole

15

Electric housing

16

Feedthru capacitor

17

Terminal board

18

Fixed column

19

Terminal cover

20

Back cover

21

Bottom cover

 

 

 

 

Basic Parameter

Input Signal

Resistance: PT100, CU50, CU100, 0~500Ω, 0~4000Ω

Thermocouple: B, E, J, N, K, R, S, T

Voltage signal: -100mV~100mV

Channels

2 Channels

RTD connection

2, 3 wire

Power Supply of Fieldbus

FF/PA:9~32 VDC/Current : ≤ 14mA

HART:12~42VDC

Insulation

Between housing and terminal board:

500 Vrms (707 VDC)

Display

6-digit numeric and 5-digit alphabet LCD Display

Operation Temperature

-40 ~ 85°C (Without display)

-30 ~ 70°C (With display)

Humidity Range

0% ~ 100% RH

Start Time

≤ 5s

Update Time

0.2s

Protection grade

IP 65

EMC

Designed to comply IEC 61000 (GB/T 18268-2000)

 

RTD Specification

RTD Accuracy (25°C)

Sensor Type

Working Range(°C)

Accuracy

Resistance

0~500Ω, 0~4000Ω

±0.05%

PT100

-200 ~ 850°C

±0.2°C

PT1000

-200 ~ 850°C

±0.1°C

CU50

-50 ~ 150°C

±0.3°C

CU100

-50 ~ 150°C

±0.2°C

TC Specification

TC Accuracy (25°C)

Sensor Type

Working Range(°C)

Accuracy

Voltage

-100mV ~ +100mV

0.05%

B

500°C ~ 1810°C

±1.0°C

E

-200°C ~ 1000°C

±0.4°C

J

-190°C ~ 1200°C

±0.4°C

K

-200°C ~ 1372°C

±0.4°C

N

-190°C ~ 1300°C

±0.8°C

R

0°C ~ 1768°C

±1.0°C

S

0 °C~ 1768°C

±1.0°C

T

-200°C ~ 400°C

±0.4°C

 

 

Universal input field mounted Low-copper aluminum alloy housing temperature indicating transmitter NCS-TT105 with Hart protocol



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.